
Station configuration checked before it reaches site.
For protection, substation automation and commissioning engineers. Your relay vendor tools stay as they are.
- Standards
- IEC 61850 · IEC 62443
- Station files
- SSD, ICD, IID, SCD, CID, SED
- Records
- COMTRADE 1991, 1999 and 2013
- Works with
- SCL from PCM600, System Configurator and other IEC 61850 tools
- Deployment
- Self-hosted, your cloud or air-gapped
What your team gets
IEC 61850 engineering without leaving the IDE.
Govern features are in use today. Domain modules are pre-release; their state is listed under Tools and formats.
Who uses it
One environment for every role on the team.
Tools and formats
What the Energy module handles, and how far each is verified.
The module is behind a setting, off by default. Loading a CID file to a relay goes through the relay vendor's tool.
No relay vendor tool or relay has been run, and no customer project opened. The module's checks are its own, not a vendor tool's acceptance. Domain modules are pre-release. Nothing is verified by a customer yet, and nothing is verified on Windows. Do not rely on a capability for production work until it is verified for your tools, versions and operating system. Product names belong to their owners.
How a change moves
A person decides before anything leaves the desk.
- ProposeAn engineer or agent drafts a change to station configuration.
- VerifySchema and consistency checks run on the files before issue.
- ApproveA push to the issued configuration waits for a named approver.
- RecordChange, results and approval kept together in the audit record.
Standards
Evidence for your engineering process. Conformance is yours.
Neural Inverse provides evidence toward these standards. Certification stays with your organisation and assessor.
Rules you work under
What they ask, and what Neural Inverse gives you toward them.
We produce records your assessors and regulators can use. We never say a product makes you compliant; that stays with your organisation.
[Draft: to be approved by legal counsel before publication]
Does it work with our relay vendor tools?
The Energy module reads SCL from PCM600, System Configurator and other IEC 61850 tools, and loading a CID file to a relay still goes through the relay vendor’s tool. The module is pre-release: its reader and checks are verified on 292 public sample files, and no relay vendor tool or relay has been run yet.
Can an agent write to a relay or change issued configuration?
Online IEDs are browsed read-only over MMS, without writing to them. A push to the issued configuration waits for a named approver, and agent rules keep agents off the station and plant networks you name.
Can it run on-premises or air-gapped?
Yes. Neural Inverse Govern runs on your own servers, in your own cloud account or on a network with no internet access, installed from an offline bundle with checksums and with models served inside your network. Run each release on a host with no route out before you rely on it.
Can we keep station files on models we host?
Yes. Each request is classified from its project, and your routing policy decides which models may serve each classification. By default, restricted work may only reach self-hosted or zero-retention models.
Is Neural Inverse certified for NERC CIP or IEC 62443?
No. Neural Inverse does not make you compliant with NERC CIP or certify anything to IEC 62443. Govern keeps records of changes, approvals and decisions as evidence toward your controls; compliance and certification stay with your organisation, its auditors and assessors.
Products used
Product names belong to their owners.

Talk to our team.
Neural Inverse is available by request. We work with your engineering, security and procurement teams from the first conversation.